Home Insulation Grants Boilers Prices


Home Insulation Grants Boilers Prices

Home Insulation Grants Boilers Prices
  • Offshore price : $8,999.00 - $100,000.00
  • Minimum order quantity : 1 set
  • Supply Capacity : 10 units/month
  • Manufacturer/Brand : TOBO BOILER
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA
I need the quotation of for Ton/KW , the fuel is , use for ,My name is , my Email is ,my phone number is , Please Send the detail information for me!

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

meter to boiler pipe size | PlumbersForums.net

Jun 04, 2019 · jrmroxx. Hi, In the near future would like to change standard boiler for either same or combi, meter is at one corner of house and boiler diagonally opposite, pipe starts at 22mm from meter but ends up 15mm at boiler, concrete floors so assuming pipe goes up to and into 1st floor cavity and accross approx 45'.

Get Price

Boiler size | Page 2 | DIY Home Improvement Forum

Jul 11, 2009 · Once you adjust the proper flow through the boiler and size the boiler properly, this is the most efficient operation. If the flow in the boiler exceeds the rate to be less than a 20f delta T the water will take a long time to heat up. The flow should normally be between 20f to 40f. Slow the flow down in a boiler it get hotter faster.

Get Price

Coal Boiler Size - Page 2 | Stoker Coal Boilers Using

Apr 12, 2011 · Stoker Coal Boiler: KEYSTOKER Kaa-2 Hand Fed Coal Stove: Hitzer 50-93 & 30-95, Vigilant (pre-2310), D.S. 1600 Circulator, Hitzer 254 Post …

Get Price

Replacement Gas Boiler Installation – What Size Boiler

Dec 21, 2021 · Ignore all advice which tries to match a boiler to the number and size of radiators. - It is better to have oversized radiators to allow your boiler to run at lower flow temps (and condense more) - Older boilers (not sure how old yours is) were designed to run at an 11 degree delta. Modern condensing boilers run at a 20 degree delta.

Get Price

Boiler upgrade savings | Page 2 | Screwfix Community Forum

Mar 09, 2006 · Walter systems, I would be most obliged if you could give me the safety devices fitted to a sealed combination boiler. Regards. Log in or Sign up. Screwfix Community Forum. Home Forums > Screwfix Community Forum > Plumbers' Talk > Boiler upgrade savings. Discussion in 'Plumbers' Talk' started by derrent, Mar 8, 2006. Page 2 of 2 < Prev 1 2

Get Price

Condensing bolier flow and return temps - effect on rad

Nov 22, 2014 · Ok so hear goes I work my room heat losses out @ delta 50 1 degree = 2% i up size by 20% which gives me a delta 40 heat figure for each room. I then work out the system requirement and add 10% for pipework heat loss. I range rate the boiler through the perameters at a Max of this figure. I set flow temp to 65 allowing room temp to be 15..

Get Price

Assistance in sizing a new hot water boiler? | Page 2

Oct 20, 2021 · The venting may or may not be done, even if moving from a 75-80% boiler to a mid-efficiency boiler of the same burner size. The venting would in many or most cases NOT be done if downsizing the cast iron boiler for a better fit to the actual load, and would need a right-sized flue liner to improve stack velocity in order to reduce risk of backdrafting &/or flue condensation.

Get Price

Pump Sizing | Page 2 | PlumbersForums.net

Jul 14, 2021 · That's my point mate. Yes the boiler will modulate but what when it's -2°c outside, the boiler is at full output and then you switch on an electric cooker, plus your 1 or 2 32 amp ring mains and your lighting circuits etc etc. Admittedly this is an extreme situation scenario but like heating systems shouldn't all electrical systems be designed with max load in consideration?

Get Price

Size of boiler | Page 2 | Screwfix Community Forum

Jun 11, 2015 · The other one said to useconventional system boiler; Vaillant Eco-Tec Plus 438 heat only boiler with 300 litres megaflow and 100 litre capacity expansion vessel for heating with two pump one 15 for hot water in summer time when the heating is off and a ( UPS2 25-80 (180) A+ Eff. Domestic, Light Commercial Heating pump ) on heating flow pipe

Get Price

boiler install gas pipe size | PlumbersForums.net

Sep 19, 2020 · The manufacturer's data will tell you exactly, but a 35 kW boiler will require around 3.8 cubic metres of gas per hour. 4. A 25 metre run of 22 mm pipe will only support a flow rate of 2.6 m cubic metres / hour, so is inadequate. 5. Subject to a specific site survey, you would need 28 mm pipe for the run. 6.

Get Price

Replacement boiler sizing in SE MA | Page 2 | Terry Love

Feb 01, 2021 · Home Forums > Water Heater Forum & Blog > Boiler Forum > Replacement boiler sizing in SE MA. Discussion in 'Boiler Forum' started by Peter Noble, May 7, 2019. Page 2 of 2 < Prev 1 2. Dana In the trades. Joined: Jan 14, 2009 Location: 01609. A common rule of thumb for short cycling are burns shorter than 5 minutes, more than 5 burns per hour.

Get Price

Replacement boiler sizing in SE MA | Page 2 | Terry Love

Feb 01, 2021 · Home Forums > Water Heater Forum & Blog > Boiler Forum > Replacement boiler sizing in SE MA. Discussion in 'Boiler Forum' started by Peter Noble, May 7, 2019. Page 2 of 2 < Prev 1 2. Dana In the trades. Joined: Jan 14, 2009 Location: 01609. A common rule of thumb for short cycling are burns shorter than 5 minutes, more than 5 burns per hour.

Get Price

How do you calculate what size boiler? | OT (OFF Topic) Forums

Mar 27, 2021 · I also spoke to the boiler folk and decided to stick with the Veissmann 30Kw in the end which should be plenty. We're not intending to extend the house or anything that might warrant a larger boiler. Also apparently to go to the 35kw we would need to change the main feed and return from 22 to 28mm so an additional faff though not really an

Get Price

Vaillant Boiler Size | Page 2 | PlumbersForums.net

Dec 09, 2021 · Even with range rating the minimum output of the 837 is still 12 kw? and it can't be range rated below this. An 838 will go down to 7.1kw. The 837 is the old model, so the OP may find the newer 838 is better for his system.

Get Price

Boiler Forum | Page 2 | Terry Love Plumbing Advice

Nov 24, 2021 · Boiler Forum. Page 2 of 93 < Prev 1 Assistance in sizing a new hot water boiler? jasesun23, Oct 15, 2021 2. Replies: 24 Views: 450. John Gayewski Oct 20, 2021. Unusual set up: indirect as preheat for small combi? greenmountain, Oct 14, 2021.

Get Price

Boiler kw sizing - Page 2 - Boilers & Hot Water Tanks

Nov 20, 2021 · The MI's for the boiler will suggest that a system volume calculation be done to ascertain the total volume / temp / expansion and more is added to meet the system requirements. I would say you'd be around 12-14L to allow a good chunk of headroom, so adding another 7-8L would be what I would be doing if I was fitting that lot.

Get Price

Boiler Sizing | Page 2 | DIYnot Forums

Oct 11, 2021 · DIYnot Forums. Home Forums > How to Boiler Sizing. Discussion in 'Plumbing and Central Heating' started by padstar, 26 Nov 2021 at 4:49 PM. Page 2 …

Get Price

What size of gas boiler - Page 2 — MoneySavingExpert Forum

Jan 02, 2015 · Also, do you really need to size the boiler for a lowest outside temperature of -5º C? That will almost certainly be hit in the middle of the night when the heating won't be running. And then only perhaps once in the lifetime of a condensing boiler (10 years). For sizing a boiler, a few kW either way won't make much difference.

Get Price

Boiler size & cost - Page 2 — MoneySavingExpert Forum

Mar 28, 2021 · Boiler size & cost. He thinks that if fixed, the boiler could get us through another year or 2 until we have the utility room ready so we can then install directly the Megaflow system, saving money. I am hesitant as keep throwing money on an old boiler doesn't make sense but on the other hand, it might be worth trying. Always remember

Get Price

Gas-fired water boiler - Weil-McLain

Soft lockouts will not cause an alarm. In addition to mounting and wiring the AM4 module to each boiler operated by the multiple boiler controller, you will need to program the Ultra Control Module of each boiler to accept a 0 - 10 vdc input signal, as described in these instructions. (AM4 kit allows the Ultra boiler's modulation to be

Get Price

Choosing a boiler sizing by heat loss or radiation BTU

Oct 26, 2013 · The P/S setup with the thermic on the boiler loop provides the 'best of both worlds' for the most part. Heat call comes, pumps start, there is full flow through the system. Boiler comes up to temperature and as the thermic valve begins to open, hot water will begin to be injected into the system.

Get Price

Heat Loss Calculation / Boiler Sizing - Page 2 | Stoker

Nov 14, 2014 · Stoker Coal Boiler: VanWert VA400 Coal Size/Type: buckwheat Other Heating: oil. Post by dvholding » Fri. Nov. 14, 2014 8:13 pm I used my va400 for the first time last season 2013-2014. I purchased it about 17 years ago from an 80 year old gentleman that was converting to oil. At that time fuel oil was $0.50 a gallon.

Get Price

Finding temperature offset from boiler to grouphead - Page 2

Sep 04, 2021 · This is because there is a flux of themperature from the wall of the boiler that cross the water inside and finally reach the gouphead. There is a lag of the wave of heat form the boiler to the grouphead. At the grouphead the temperature is much more stable (92 to 96°C) than at the boiler (96 to 108°C). But I have notice that there is steam

Get Price

Condensing boiler radiator sizing - CHIC | Page 2 | DIYnot

Jun 09, 2010 · (Some size the boiler first and then the rads, but that's not relevant to the explanation.) The important thing is that there's no point buying a boiler which is larger than the total rad output. So you need a 15kW boiler and 15kW of rads, but you want the boiler to condense even when the outside temperature is at the lowest you have chosen

Get Price

gas pipe size and combi boiler failures. - Page 2

Jul 19, 2011 · We've had endless trouble with our 6 year old combi boiler - I've now got quotes for a new "regulation" /no choice condensing boiler. All the quotes specify replacing the existing 6 metres of 15mm diameter copper pipe from the meter to the current boiler with a 22mm dia. pipe; could the 15mm pipe size be the cause of fairly regular combi boiler shut downs?

Get Price

Boiler flame too big? - Page 2 — Heating Help: The Wall

Observed the boiler for a while, looks like the flash back was a result of delay ignition. Ignition didn't happen till 2-3 seconds after the gas valve opened. Took the polit apart and cleaned it. Polit flame looks a lot more like it was before the new valve, a lot longer and is actually blue now Boiler runs alot smoother and quiter now.

Get Price

Boiler Sizing | PlumbersForums.net

May 29, 2021 · Discuss Boiler Sizing in the Central Heating Forum area at PlumbersForums.net. P. Paulhar. Messages 20. Jul 25, 2021 #1 Hi All, I'm trying to work out a boiler size for a huge, four storey victorian property, part of which is already heated. I'll be adding a second boiler, 18 rads and a cylinder. Is there a heat loss calculator online somewhere

Get Price

Size expansion tank for 1000 gallon storage? | Page 2

Oct 08, 2012 · My system volume will roughly be around 1250 gals (two 500g storage tanks, 750' 1.5" UG, boiler, and this homemade expansion tank). The elevation change works against me too since the home sits on about 15' higher ground than the pole barn where boiler and storage sits.

Get Price

Boiler for Graham TVR1ABB? - Page 2 - RC Groups

Nov 04, 2019 · I dont know of a compendium with engine vs. boiler sizing guidelines. What I'm telling you is my own experience. Regarding boilers it is always better to err on the large side. Because you can't really make a small/low performance boiler put out more steam and when you notice that the steam engine slows down "out of breath" it is too late

Get Price

boiler sizing! boiler sizing!!!!?! | PlumbersForums.net

Jun 17, 2017 · Hello all, I notice than no-one has mentioned the `Whole House Boiler sizing method` calculation which is supposed to be `the Industry Standard` for calculating the size of a new Boiler since about 2003 and was reinforced by Part L Energy Efficiency Regulations. Also - the Energy Efficiency Exams that all Heating Installers / Heating Engineers HAD TO PASS in …

Get Price

OT -best advice how to remove a locomotive boiler steam

Jan 10, 2022 · Had a look at the Kali Code..killer is the 5 cu ft gross volume,including firebox and smokebox .that is going to severely limit the size of a loco boiler..There is a steam trike on utube,the boiler is very simply made from a LP gas tank from a car inside a 50 gal oil drum..The driver/rider /engineer simply pours in a 2l bottle of water,refits the plug,and off he goes until …

Get Price

AA 260 Chimney Size - Page 2 | Stoker Coal Boilers Using

Oct 11, 2018 · Stoker Coal Boiler: Keystoker KB-8 Coal Size/Type: Buckwheat Other Heating: Utica Propane Hot Water. Post by Olllotj » Wed. Oct. 10, 2018 8:29 pm The 260 is a big boiler. I am surprised the breech is only 6" My Keystoker has 100k less available BTU and has a 9" breech. But they're so different in ever way. Top .

Get Price

Help- boiler heating past set temperature - Page 2

Nov 30, 2021 · If you can, close the incoming make-up water valve first and then reduce the pressure to 20# hot or 15# cold. With the make-up valve closed the only thing that will affect the pressure is the boiler operation and the pressure will either stay at one level (20-25# is OK) or may fluctuate with 15# as the low pressure.

Get Price

Advice on combi boiler | Page 2 | DIYnot Forums

Sep 26, 2015 · A.2 Meter size calculation To calculate the size of meter required, multiply the maximum heat input of each appliance by its diversity factor, add these figures, convert to megajoules, and divide the total by the calorific value of the gas (typically 39 MJ/m3 for 2nd family gas). The following is an example of such a calculation. Table A.1

Get Price

Boiler just died - Page 2 - DoItYourself.com Community Forums

Jan 15, 2007 · Boilers - Home Heating Steam and Hot Water Systems - Boiler just died - HVAC-EMT, thanks that is very helpful information. it appears that i will end up putting same capacity boiler as the previous one.it seems highly unlikely that any heating companies will recommend a smaller boiler..unless I take a chance and

Get Price

Sizing a Boiler for Hydro Air? | Page 2 | Plumbing Zone

Nov 22, 2010 · Sizing a Boiler for Hydro Air? Jump to Latest Follow 21 - 28 of 28 Posts. Prev. 1; 2; 2 of 2 Go to page. Go A forum community dedicated to professional plumbers. Come join the discussion about the industry, safety, finishing, tools, machinery, projects, styles, scales, reviews, accessories, classifieds, and more!

Get Price

Boiler sizing using HDD Therms - Page 2 — Heating Help

So the 80k BTU boiler is actually a 54k BTU boiler at 8'000 altitude. While it may be in the manual, that number is almost certainly incorrect. I have ASHRAE papers from 1933, 1952, and 2007 on the subject and current consensus among industry experts is something like 1.8% per 1,000 ft ASL for a natural draft appliance.

Get Price

PSE single cylinder boiler size - Page 2 - The Unofficial

077-080 Boiler with Bricked Firebox and Immersion Heater Model#'s 20, 20G, 55, 55G, 95G Is that the above? For only $196.50?? PSE single cylinder boiler size - Page 2 - The Unofficial Mamod & Other Steam Forum

Get Price

undersized boiler | Page 2 | Screwfix Community Forum

Apr 16, 2007 · TM, you say 80k boiler is minimum size. I wonder where you got this figure. Of course 80k will be the smallest boiler IF IT IS A COMBI. Heat loss has to be calculated for each room, HW cylinder load factored in, a percentage allowance applied (wonder if still needed what with global warming) and then you have a total that a boiler needs to deliver.

Get Price

Piping diagram for one boiler and two storage tanks | Page

Jun 04, 2013 · I'm talking open loop boiler systems strictly for heating Around here the heating system and Dom hot water systems are two separate systems I've seen a few lager systems that had steam boilers and used steam heat exchangers to heat domestic hot water these are few and far between like at the hospitals and universities I guess those are a kind of indirect heating …

Get Price

Matching boiler size to radiator output - Page 2 — Heating

Feb 01, 2021 · PS. I wish you served this area. We sure need good hydronic specialists. I was looking at my neighbor's newer system, with a Lochinvar Knight water tube boiler capable of producing up to 378,000 BTUs for a house smaller than mine. And the boiler started and quickly ramped up to and then cycled off, and the circulators turned off as well.

Get Price

Boiler problems that HVAC company can't solve - Page 2

Jan 10, 2022 · You shouldn't need any more than 12 psi in your system, unless you're more than a 2 story home. A boiler bypass is crucial on your system. That Weil McLain is a great little boiler and should last a long time but it will condense if return water temps of less than 130 - 135 F are coming back to it for any length of time.

Get Price

Original Boiler Sizing (From 1927) - Page 2 — Heating Help

10 Gorton G-2 have been added. No info on the boiler, but I know it came with a coal shovel as my Grandfather stoked the fires. Was converted to oil and now is NG. The entire project was $39,856.89. Paid for by donations at the time with an excess of $32.49 balance left in the budget.

Get Price

Keystoker boiler size advice - Page 2 | Stoker Coal

Apr 18, 2019 · The kaa-2,kaa-4 and kaaKefid have the identical size flat 3 bed wide coal burning grate. In my case the kaaKefid was a real energy hog when it ran on oil and it is very noisy when running on oil. I am going to assume the same occurs when it runs on natural gas or propane.

Get Price

Boiler gas supply pipe sizing | Page 2 | DIYnot Forums

Apr 06, 2016 · DIYnot Forums. Home Forums > How to > Plumbing and Central Heating > But even if a little low like 2 mbar pressure loss, the boiler will work fine. The risk is solely that under the warranty the makers have an excuse not to cover it. Advice needed on the correct size of boiler and gas supply pipe please. hztm2008

Get Price

How do you calculate what size boiler? | OT (OFF Topic) Forums

Mar 27, 2021 · I also spoke to the boiler folk and decided to stick with the Veissmann 30Kw in the end which should be plenty. We're not intending to extend the house or anything that might warrant a larger boiler. Also apparently to go to the 35kw we would need to change the main feed and return from 22 to 28mm so an additional faff though not really an

Get Price
Hey, let me help you!